Assessment of Aquifer Protective Capacity, Against the Surface Contamination. A Case Study of Kaduna Industrial Village, Nigeria
Physical Science International Journal,
Page 43-51
DOI:
10.9734/psij/2022/v26i130306
Abstract
Geo-electric soundings was carried out in 22 different locations at Kaduna Refinery Petrochemical Corporation (KRPC) and White Oil and Gas Layout, Mahuta, Kaduna. The aquifer protective capacity and Hydraulic characteristics of the study area was computed from the Geoelectric parameters using Dar-Zarrouk and hydrological parameters. The interpreted data were presented in tabular form, Geoelectric/geology soil profiles and contoured maps. The results show that the study area aquifer is relatively protected with an average value of 0.5 mhos with an indication of infiltration of contaminant in some location. The hydraulic parameter values also show that the study area aquifer has the capacity to produce water non-stopping if the wells are sited based the geophysical investigation. The computed hydraulic characteristics and transmissivity of the area has an average value of 5.5 m/day and 6.1 /hour, which implies that, the study area has the capacity to transmit groundwater through a distance of 5.5 m in 24-hour and can covers 6.1 in one hour.
Keywords:
- Protective capacity
- hydraulic characteristics
- transmissivity
- Dar-Zarrouk parameters
How to Cite
References
Alao Joseph Omeiza, Dogara Matoh Dary. Aquifer vulnerability to surface contamination: a case of the new millennium city, Kaduna, Kaduna State Nigeria. World Journal of Applied Physics. 2018;3(1):1-12.
DOI: 10.11648/j.wjap.20180301.11
Fatoba1 JO, Omolayo SD, Adigun EO. Using geoelectric soundings for estimation of hydraulic characteristics of aquifers in the coastal area of Lagos, Southwestern Nigeria. International Letters of Natural Sciences. 2014;11:30-39. doi:10.18052.
Oladapo MI, Akintorinwa OJ. Hydro-geophysical study of Ogbese South western, Nigeria. Global Journal of Pure and Applied Science. 2007;13(1):55–61.
Aderemi FL, Bamiro MR. Estimation of aquifer protective capacity using geoelectric method in Odo Ona Elewe, Ibadan, Nigeria. J. App. Geol. and Geophysics. 2021;9(1):32-38.
Alao JO, Dogara DM, Abdulhadi D, Samson EE. Comparative assessment of half schlumberger configuration as an alternative method to the conventional schlumberger configuration at trade centre, Mani-Nissi Village, Kaduna, Nigeria. SSRG International Journal of Applied Physics (SSRG-IJAP). 2019;6(3):51-56.
Dogara MD, Aboh HO, Alao JO, Kogi KA. The aquifer overlying the basement complex in some parts of dan-hono, Kaduna, Nigeria. KADA Journal, Department of Physics, Kaduna State University, Kaduna. 2017;(1) 2:45-52.
Dogara MD, Alao JO. Preliminary estimate of gypsum deposit based on wenner and schlumberger electrical resistivity methods at Ikpeshi, Edo State, Nigeria. Science World Journal. 2017; 12(2):19-23.
Available:www.scienceworldjournal.org.
Danlami A, Gazara A, Ango A,Aalo JO. Investigation of groundwater potential by correlating geo-electrical parameters at babban saura in chikun local government area of Kaduna State. Katsina Journal of Natural and Applied Sciences. 2019;8(1). (ISSN: 2141-0755)
Aboh HO, Dogara MD, Alao JO. Evaluation of the geotechnical parameters in part of Kaduna, Kaduna State Nigeria. World Journal of Applied Science and Technology. 2016;8(2):108 -117.
-
Abstract View: 143 times
PDF Download: 51 times